Leku-Ona offers connectors DIN2353 manufactured and treated with the new coating processes that offer high resistance to salt spray. Since 2010 we have developed a research process that was based on the use of treatment with 320 A3C resistance. This process evolved into A3B (CrVI-free) and then to ZnNi (720 hours). Currently, it has begun to implement a new treatment called ZnNi NEW which is giving us high performance corrosion arriving at 3000 hours
APLICATIONS.
- Whenever a high corrosion resistance is required
- Temperature changes do stress additionaly
ADVANTAGES
- High corrosion resistance of the coating and base material
- Capable for flaring and bending
- Log term protection, even under thermal stress
- High availability
- Low maintaining costs within the application
TECHNICAL DETAILS
COMPARISON OF LAYERS
This chart shows a comparison of the type of treatment in the various processes A3C, A3B and Zn / Ni
SALT SPRAY TEST
Description:
- The following pictures indicate the corrosion resistance of Volz Zinc-Nickel
- plated parts with sealer
- Within the galvanisation process, these parts got handled in a drum
Indication of corrosion:
- Parts with assembled nuts show red rust after 1.872 hours
- This is a forced result as the salt water couldn‘t disappear at this point
- Other parts, where the salt water was able to disappear (as required by the ISO
- 9227:2006), show red rust within the band of 3.072 / 3.216 / 3744 hours
168 HOURS
1032 HOURS
2064 HOURS
3192 HOURS
5280 HOURS